Design

Steam Turbine Condenser. https://truecload763.weebly.com/graphic-3-1.html. A.k.s.raghava Flow Cycling: A Holistic Process in for A Power Plant A Device to Convert Dead Steam into Live Water Water ready to take Rebirth Dead Steam Layouts of A Condenser Layouts of A Condenser An Integral Steam Turbine and Condenser System Steam Condenser Steam condenser is a closed space into which steam exits the turbine and is forced to give up its latent. Small cubed mailsuite 2019 0 1. Secop – SETTING THE STANDARD Secop. Condenser Heat Exchanger is very common in process industry, condensers may be classified in two main types; Condensers which have a coolant and a condensing vapor brought into direct contact and other types which have the coolant and a condensate stream separated by a tube wall or a solid surface. This Software deals with the type where the streams are separated when condensation occurs.

CONDENSER DESIGN Condensation on horizontal tubes (Nusselt theory) Heat transfer coefficient is obtained by h=0.728[kL3 ϸL(ϸL- ϸV)g ƛ /µL (Tv –TW) D] Where kL – thermal conductivity of liquid ϸL – density of liquid ϸV –density of vapour ƛ – latent heat of condensation of steam g- Gravitational acceleration =9.81m/s2 µL – viscosity of liquid TW – temperature of surface Tv –temperature of vapour D –diameter The above eqn applies for a single tube or single row of tubes. When tubes are stacked over each other the heat coefficient is calculated as H=h NR-1/6 Nr- no of rows of horizontal tubes
As the properties(kL, ϸL, µL) of the condensate changes with the temperature ,so some modifications are being done to compensate for that . Tf =βTw +(1- β)Tsat Where β-weight factor (recommended in the literature from 0.5 to 0.75) Condensate sub cooling The temp in the condensate film drops from Tsat at the liquid vapour interface to Tw at the wall. Therefore the avg condensate temperature, TL is less than Tsat, and hence the condensate leaving the surface is sub cooled. Accounting for sub cooling, the rate of heat transfer is Q=W ƛ +WCp,L (Tsat - TL)= Whfg*
Cp,L heat capacity of condensate W- condensation rate to account for both sub cooling and inertial effects h/hNu =(1+(0.683 -0.228 PrL-1)Ԑ)^0.25 hNu - heat transfer coeff by basic nusselt theory Ԑ- Cp,L (Tsat - Tw)/ƛ PrL - Cp,L µL/ kL above eqn is valid for Pr>0.6 Q=NhD0L∏(Tsat - Tw) Tw=…………… Then Tf can be obtained by the eqn given above Mass flow rate of water =ϸAu U –flow velocity A of tube can be calculated from the above eqn And the total area= N∏DL And the condensation rate –Q/hfg* Some FACTS to remember 

In drop wise condensation Heat transfer coefficient is considerably high as compared to film condensation. The reason being the direct contact of vapor with the cooler surface. The effectiveness of a condenser can be calculated as (1 - eNTU) NTU=(UA/Cmin) Cmin=(mCp)min
References –process heat transfer principles and applications by ROBERT W SERTH Heat and mass transfer –cengel and ghajar

Condenser Design Calculation Pdf Reader 2017

PROCESS DESIGN OF SHELL AND TUBE HEAT EXCHANGER, CONDENSER AND REBOILERS. Airmail 3 6 58 coupe. Calculation of heat transfer co-efficient. Type of heat exchanger and design pressure. Alldata program free. Downloads lagu opick taubat. The optimum thermal design of a shell and tube heat exchanger involves the. Tube heat exchangers calculations it is very important to remember some. Sandhya namam lyrics in malayalam pdf software. Tower Design Free Online eBook Collection at: www.pdftop.com/ebook/tower+design. Thermal design calculations of Shell & Tube condensers for horizontal condensers, vertical condensers including reflux condensers; main features: +Support S.I.